Find the Right Sensor for Your Monitoring Application
No matter what the monitoring application is, Franklin Electric offers a sensor solution tailored to the specific requirements of each environment.
Need to distinguish between fuel and water?
Discriminating Sensors not only detect the presence of liquid within a containment area but also differentiate between hydrocarbons and water, triggering appropriate alarm signals.
Only need to detect the presence of liquid?
Non-Discriminating Sensors provide reliable liquid detection, alerting you to the presence of any fluid inside a containment space without identifying the liquid type.
Which EVO™ Automatic Tank Gauge (ATG) are you using?
Use the chart below to find the correct sensor model number compatible with your EVO™ ATG system — whether it’s the EVO™ 200/400, EVO™ 550/5000, or EVO™ 600/6000.
Sensor |
Discriminating Dispenser Sump Sensor |
Discriminating Turbine Sump Sensor |
Discriminating Magnetostrictive Sump Sensor |
Universal Liquid Sensor |
Universal Hydrostatic Sensor |
Electro-Optic Interstitial Sensor |
Discriminating Interstitial Sensor |
Hydrostatic Interstitial Sensor |
Corrosion Detection Sensor |
Desiccant Pack Sensor |
Discriminating Capability |
✔️ |
✔️ |
✔️ |
✔️ |
✔️ |
✔️ |
✔️ |
✔️ |
- |
- |
Non-Discriminating |
- |
- |
- |
✔️ |
✔️ |
✔️ |
- |
- |
✔️ |
✔️ |
Turbine Sump Applications |
- |
✔️ |
✔️ |
✔️ |
✔️ |
- |
- |
- |
- |
- |
Dispenser Sump Applications |
✔️ |
- |
✔️ |
✔️ |
✔️ |
- |
- |
- |
✔️ |
- |
Tank Interstitial Space Applications |
- |
- |
- |
- |
- |
✔️ |
✔️ |
✔️ |
- |
- |
Tank Ullage Applications |
- |
- |
- |
- |
- |
- |
- |
✔️ |
- |
- |
Position Sensitive (Tamper Protection) |
- |
- |
✔️ |
- |
- |
- |
- |
- |
- |
- |
Hydrostatic Monitoring Capability |
- |
- |
- |
- |
✔️ |
- |
- |
✔️ |
- |
- |
EVO™ 200/400 Model Number |
FMP-DDS-U |
FMP-DTS-U |
TSP-DMS |
FMP-ULS |
FMP-UHS |
FMP-EIS-U |
FMP-DIS-U |
FMP-HIS-U FMP-HIS-XL-U |
FMP-CDS-U |
FMP-DPS-U |
EVO™ 550/5000 Model Number |
FMP-DDS |
FMP-DTS |
TSP-DMS |
FMP-ULS |
FMP-UHS |
FMP-EIS |
FMP-DIS |
FMP-HIS |
- |
- |
EVO™ 600/6000 Model Number |
FMP-DDS, FMP-DDS-U |
FMP-DTS, FMP-DTS-U |
TSP-DMS |
FMP-ULS |
FMP-UHS |
FMP-EIS, FMP-EIS-U |
FMP-DIS, FMP-DIS-U |
FMP-HIS, FMP-HIS-U, FMP-HIS-XL, FMP-HIS-XL-U |
FMP-CDS-U |
FMP-DPS-U |
Typical Application |
Dispenser sump applications requiring discriminating capabilities |
Turbine sump applications requiring discriminating capabilities |
Containment sump applications requiring discriminating capabilities with tamper protection regulations in place |
Containment sump and steel double wall tank applications |
Brine-filled double wall containment sump and tank applications |
Dry double wall steel and wrap-around fiberglass tank applications |
Dry double wall steel and wrap-around fiberglass tank applications requiring discriminating capabilities |
Brine-filled double wall tank applications requiring high brine vs. low brine detection |
Monitoring for corrosive environments |
Monitoring remaining life of the Desiccant Pack(s) |
EVO™ 600/6000, EVO™ 550/5000 may support additional sensors. Sensors with "-U" that are used with the EVO™ 600/6000 wire to either a Universal Device Protocol Module (FMP-UDP9) or a Probe Module (TS-PRB). FMP-DDS, FMP-TDS, FMP-EIS, FMP-DIS, FMP-HIS and FMP-HIS-XL all require a 3-Wire Sensor Module (TS-3WSNS).