This 2 x twisted pair instrumentation cable is ideal for connecting multiple probes, sensors, and low-voltage devices to tank gauges and monitoring systems in fuel installations. The cable features a robust, blue LSZH sheath, making it well-suited for intrinsically safe environments where flammable gasses may be present.
The dual twisted pair configuration enhances signal integrity, even in environments with strong electromagnetic interference (EMI). Its low smoke zero halogen (LSZH) construction ensures minimal smoke and toxic emissions, protecting sensitive equipment and personnel safety in critical locations.
Applications:
- Multi-sensor tank monitoring systems
- Fuel level probes and leak detection devices
- Petrol station forecourts and fuel depots
- Backup generator fuel system installations
- Industrial storage tanks and refineries
LL3-SENSOR-CBL-2PAIR Cable Specifications
Application
These cables are designed to connect electrical instrument circuits and provide
communication services in and around process plants (e.g., petrochemical industry).
Pairs are individually shielded for enhanced signal security. Not suitable for direct burial applications.
Ideal for installations where fire, smoke emissions, and toxic fumes pose potential risks to life and equipment.
Characteristics
- Voltage Rating: 300V
- Operating Temperature: Fixed: -40°C to +80°C | Flexed: 0°C to +50°C
- Minimum Bending Radius: 6 x overall diameter
Construction
- Conductor: 0.75mm²: Class 5 flexible Copper
- Insulation: XLPE (Cross-Linked Polyethylene)
- Individual and Collective Screen: Al/PET (Aluminium/Polyester Tape)
- Drain Wire: Tinned Copper
- Sheath: LSZH (Low Smoke Zero Halogen) - UV and Fuel Resistant
- Core Identification: Pairs: White, Black, numbered
- Outer Sheath Colour: Blue
Standards and Regulatory Compliance
- Standards: EN 50288-7, EN 50288-1, EN 60228, HD383
- Flame Retardant: IEC/EN 60332-1-2, IEC/EN 60332-3-24
- Low Smoke Halogen-Free: IEC/EN 60754-1/2, IEC/EN 61034-2
- UV Resistant: UL 1581-1200
- This cable meets the requirements of the following directives:
- Low Voltage Directive 2014/35/EU
- RoHS Directive 2015/65/EU
- Reach Directive EC 1907/2006
Technical Characteristics
- Nominal Voltage: 300V
- Flame Retardant: IEC/EN 60332-1-2
- UV Resistance: UL 1581-1200
Available Sizes and Dimensions
No. of Pairs |
Nominal Cross Sectional Area (mm²) |
Nominal Overall Diameter (mm) |
Nominal Weight (kg/km) |
2 |
0.75 |
8.3 |
298 |
Electrical Characteristics
Nominal Cross Sectional Area (mm²) |
Mutual Capacitance (pF/m) |
Minimum Insulation Resistance (GΩ/km) |
Maximum L/R Ratio (μH/Ω) |
0.75 |
115 |
>10 |
25 |